GE Reason Switches
Chapter 7
– Configuration
136
REASON SWITCHES-TM-EN-3
o
Non-Recurring DST configuration:
Month: select the month when the DST should begin (if at
Start Time Settings) or end (if at End Time Settings);
Date: select the day of the month when the DST should
begin (if at Start Time Settings) or end (if at End Time
Settings);
Year: select the year when the DST should begin (if at Start
Time Settings) or end (if at End Time Settings);
Hours: select the hour of the day when the DST should
begin (if at Start Time Settings) or end (if at End Time
Settings);
Minutes: select the minute of the hour when the DST
should begin (if at Start Time Settings) or end (if at End
Time Settings).
o
Offset: set the offset that will be applied at the internal clock at the
DST period, in minutes. This value will be added at the internal
clock during the DST.
After change one of the configurations described before, the user may save or
discard them.
o
Save: save configuration at the Running Config;
o
Reset: undo changes made locally at the Running Config.
2.5
Log
System Log Configuration menu allows the user to configure log messages that may
be send to a server. Reason Switches send Log Messages through UDP protocol, as
defined in RFC 5426. The port used is 514.
System Log Configuration menu is located at Settings
System
Log.
Server Mode:
This field is used to enable/disable the send of Log messages. By default, it is
disabled. To enable, select Enabled in the Mode list and then configure a valid IP
address server.
Server Address:
Содержание T1000
Страница 2: ......
Страница 11: ...Figure 97 T1000 dimensions 298 Figure 98 S2020 and S2024G dimensions 299...
Страница 12: ......
Страница 41: ...Chapter 3 Hardware Design GE Reason Switches REASON SWITCHES TM EN 3 41 Figure 4 S2024G Switch...
Страница 103: ...GE Reason Switches Chapter 4 Functions REASON SWITCHES TM EN 3 103 Figure 64 Data Monitor Flow Network...
Страница 256: ......
Страница 274: ......