3
Hardware Reset
Reason Switches allow the user to reset its configuration to factory default. To do this
it is necessary to follow the steps given below.
If the switch is powered-off:
Connect Ports 1 and 2, creating a loop at the switch;
Power-up the switch;
Disconnect Ports 1 and 2.
If the switch is powered-on:
Connect Ports 1 and 2, creating a loop at the switch;
Do a reboot at the system with port 1 and 2 connected to each other. The
reboot could be done in the Web Interface or using the Reboot button (only
in T1000);
Disconnect Ports 1 and 2.
After a few seconds, the system will be operating at its factory default configuration.
Factory default IP and mask are 192.168.4.88 / 24. After the reset, this is the address that should be used to access the
equipment.