Group Name for Privilege Levels selection
EPS
LACP
POE
Spanning_Tree
ERPS
LLDP
LLDP
System
ETH_Link_OAM
Loop_Protec
Private_VLANs
UDLP
Each Group Name has its own configuration for privilege levels, which is separated at
the Privilege Levels column. Possible configurations per family are as follows.
o
Configuration Read-only
: select the privilege level number which
will be allowed to only read configuration parameters. User
privilege level should be the same or greater than the Privilege
Level selected to have access at the group;
o
Configuration/Execute Read/write
: select the privilege level
number which will be allowed to read and write configuration
parameters. User privilege level should be the same or greater
than the Privilege Level selected to have access at the group;
o
Status/Statistics Read-only
: select the privilege level number
which will be allowed to only read status and statistics parameters.
User privilege level should be the same or greater than the
Privilege Level selected to have access at the group;
o
Status/Statistics Read/write
: select the privilege level number
which will be allowed to read and write status and statistics
parameters. User privilege level should be the same or greater
than the Privilege Level selected to have access at the group
After one of the configurations described before is changed, there are two buttons
that allow the user to save or discard the configurations and to refresh the web page.
o
Save
: save configuration at the Running Config;
o
Reset
: undo changes made locally at the Running Config.
Auth Method
The Auth Method menu allows configuring the method to do users authentication
when accessing the equipment interfaces. It is allowed to define if authentication is
done locally or remotely, if remote which type will be used (RADIUS or ), the
command authorization method and accounting method.
Each configuration allowed (Authentication, Command Accounting and Accounting
methods) can be freely configured from each client. Thus, it is possible to select
different methods to access via console, telnet, SSH and, in case of the
Authentication method, it is possible also to select a method to access via HTTP
protocol. Possible configurations are as follows.
Содержание T1000
Страница 2: ......
Страница 11: ...Figure 97 T1000 dimensions 298 Figure 98 S2020 and S2024G dimensions 299...
Страница 12: ......
Страница 41: ...Chapter 3 Hardware Design GE Reason Switches REASON SWITCHES TM EN 3 41 Figure 4 S2024G Switch...
Страница 103: ...GE Reason Switches Chapter 4 Functions REASON SWITCHES TM EN 3 103 Figure 64 Data Monitor Flow Network...
Страница 256: ......
Страница 274: ......