The unit also provides information on the amount of passed and lost traffic for its
Line and drop ports (sorted per the port's priority queues), and extensive errored-
frame statistics for each drop port.
Troubleshooting
If an ETHER-1000 unit is suspected of being defective, replace it with a known-
good ETHER-1000 unit and if the replacement unit functions properly return the
original to GE Multilin for repair or substitution. Ensure that the replacement unit
is configured the same (use of the Copy/Paste feature of VistaNET is
recommended). For unit removal and insertion, refer to the procedures
Replacing ETHER-1000 Unit in a System in Service
.
The following table is intended to provide the user with possible solutions to
problems that may be encountered during normal unit operation.