7 Repair procedures
TRM, Centiva/5 Plus, M1047448/CM-922026, rev. 3.50.a
7-5
Insp.
hold
Exp.
hold
Manual
breath
ASR
VCV
Adult
Fi02
50
%
Rate
10
1/Min
I:E
1:2.0
Vt
350
ml
Plimit
30
cmH2O
PEEP
3
cmH2O
I-Flow
25
L/Min
Trig.
OFF
L/Min
MV-E
3.5
12.5
L
Rate
10
40
1/Min
O2-I
50
55
%
Pmin
3
cmH2O
Ppeak
16
21
Vt-E
350
mL
cmH2O
2.5
45
8
M
S
--
Paw
cmH2O
2
4
6
8
10
12
14
16
18
20
5
10
15
Flow
L/Min
-10
20
2
4
6
8
10
12
14
16
18
20
10
-20
Normal
screen
16
13
8
3
Ppeak
Pplat
Pmean
Pmin
cmH2O
cmH2O
cmH2O
cmH2O
3
-.-
P
P
PEEP
PEEPi
cmH2O
cmH2O
7
27
MV sp
Rate sp
R
C
L
cmH2O/L/s
ml/cmH2O
/Min
0.0
0
Adult
Pediatric
Newborn
Enter
Align
touch screen
Calibrate
O2 sensor
Bypass
system test
Unlock
exp. valve
Body weight 55 kg
Ensure silver exp. valve is in place
Start system test by pressing <Enter>
SW 3.nn.p HW o/r
System test
Centiva/5
Complete system set up, seal y-piece
+
Bi-Level VG
Newborn
Trend
Retain
trend data
09:36:53
2005-03-21
7.2.1 Remove the exp.
valve
a)
Ext. power supply is
available and exp. valve
control is working
Note
The following procedures describe how to remove the expiration valve assembly of
the Centiva/5 Plus CC Ventilator when:
a.
external power supply is available and the ventilator is able to control the
expiration valve locking mechanism.
b.
no external power supply is available, but the ventilator is still able to
control the expiration valve locking mechanism.
c.
there is no power available or the ventilator is no longer able to control the
expiration valve locking mechanism.
Operate the system with the external power supply.
1.
Connect the system to line power.
2.
Turn ON the system.
3.
Wait for the automatic power-up test to finish.
4.
Activate
button
“unlock
expiration
valve”.
5.
Push the
ComWheel
to confirm
selection.
6.
The locking
mechanism
releases
the
expiration
valve
assembly.
7.
The
expiration
valve can
be removed
from the
system.
8.
When re-
inserting
the
expiration
valve, the system automatically locks the valve assembly upon proper
insertion and performs a power-up test.
The re-locking of the expiration valve after re-insertion only works with an
appropriate external power supply (line or DC) connected.
Insp.
hold
Exp.
hold
Manual
breath
ASR
VCV
Adult
Fi02
50
%
Rate
10
1/Min
I:E
1:2.0
Vt
350
ml
Plimit
30
cmH2O
PEEP
3
cmH2O
I-Flow
25
L/Min
Trig.
OFF
L/Min
MV-E
3.5
12.5
L
Rate
10
40
1/Min
O2-I
50
55
%
Pmin
3
cmH2O
Ppeak
16
21
Vt-E
350
mL
cmH2O
2.5
45
8
M
S
--
Paw
cmH2O
2
4
6
8
10
12
14
16
18
20
5
10
15
Flow
L/Min
-10
20
2
4
6
8
10
12
14
16
18
20
10
-20
Normal
screen
16
13
8
3
Ppeak
Pplat
Pmean
Pmin
cmH2O
cmH2O
cmH2O
cmH2O
3
-.-
P
P
PEEP
PEEPi
cmH2O
cmH2O
7
27
MV sp
Rate sp
R
C
L
cmH2O/L/s
ml/cmH2O
/Min
0.0
0
Bi-Level VG
Newborn
Trend
SW 3.nn.p HW o/r
System test
Centiva/5 +
Expiration valve unlocked.
Ready to be removed from device.
Содержание Centiva/5 Plus
Страница 1: ...GE Healthcare Centiva 5 Plus Technical Reference Manual ...
Страница 14: ...1 Introduction TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 1 8 Notes ...
Страница 20: ...2 Theory of operation TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 2 6 ...
Страница 27: ...2 Theory of operation TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 2 13 ...
Страница 30: ...2 Theory of operation TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 2 16 Notes ...
Страница 34: ...3 Post service check out TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 3 4 Notes ...
Страница 70: ...4 Test and calibration TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 4 36 Notes ...
Страница 154: ...7 Repair procedures TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a 7 48 Notes ...
Страница 178: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 2 9 1 Pneumatic diagram ...
Страница 180: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 4 9 2 Electrical diagram ...
Страница 181: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 5 ...
Страница 182: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 6 9 3 Component layout PC board B ...
Страница 183: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 7 9 4 Component layout PC board A ...
Страница 192: ...9 Schematics and Diagrams TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 9 16 Notes ...
Страница 206: ...10 Configuration and optionalization TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 10 14 Notes ...
Страница 212: ...11 Optional accessories TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 11 6 Notes ...
Страница 213: ...TRM Centiva 5 Plus M1047448 CM 922026 rev 3 50 a of 11 05 Notes ...