![GE Brivo OEC 715 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/ge/brivo-oec-715/brivo-oec-715_operators-manual_4193902050.webp)
Brivo OEC 715/785/865 Mobile C-Arm X-Ray Product
Page 3-11
CAUTION
WARNING
3.3.2.
Moving the C-Arm
Familiarize yourself with the location and mechanical operation of all controls prior to moving the C-Arm.
Use the handles provided on the C-Arm to position mechanical assemblies.
1.
Return all moving assemblies to their most compact positions. Lower the vertical column and retract
the Cross-Arm. Remove the cassette holder if fitted. (Do this before switching off the mobile C-Arm).
When the C-Arm is positioned on more than or equal to 10° incline, and the mechanical
parts are extended to their greatest length, if the cassette holder is attached, the C-Arm will
be unstable. Please be sure to put the C-Arm in its compact position.
2.
Lock all movable mechanical assembly brakes: the C-Arm orbital rotation brake, the lateral rotation
brake, the Wig-Wag brake, and the horizontal Cross-Arm brake.
3.
Press and hold the power on/off key 2 seconds on the Workstation to switch the system off. Unplug the
power supply cable and secure the power cable.
4.
Disconnect the interconnect cable from the C-Arm and coil and secure the cable around the
Workstation's handles.
5.
Disconnect the footswitch and secure it on the C-Arm. Store the handswitch in its holder.
6.
Place the C-Arm's steering handle in the normal position and unlock the wheel brakes.
7.
Guide the C-Arm by pushing with the steering handles.
Do not move the C-Arm over inclines greater than 10°. Do not move the C-Arm up or down
stairs or steps.
Do not lock the C-Arm in place on an incline greater than 5°.
Transport the system at normal speed. Get across ramps and thresholds as slow as
possible.
8.
When you reach your destination, place the C-
Arm’s
brake pedal in the locked position.
WARNING
Содержание Brivo OEC 715
Страница 9: ...Chapter1 Introduction and Safety...
Страница 34: ...Chapter2 System Overview...
Страница 36: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 3 2 2 C Arm Components...
Страница 38: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 5 2 3 Workstation Components...
Страница 40: ...Chapter3 Mechanical Positioning...
Страница 52: ...Chapter4 Start Up and Operating Control...
Страница 77: ...Chapter5 Usual Operations...
Страница 108: ...Chapter6 SpecialApplications...
Страница 139: ...Chapter7 Radiographic Film...
Страница 142: ...Chapter8 System Setup...
Страница 149: ...System Setup Page 8 8 Click any mouse button to return to normal screen...
Страница 150: ...Chapter9 Maintenance...
Страница 160: ...Chapter10 Display Messages...
Страница 162: ...Chapter11 Labels and Symbols...
Страница 167: ...Labels and Symbols Page 11 6 18 1 System rating plate indicates manufacture information and input power requirements...
Страница 168: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 11 7 19 1 X ray Generator rating plate Total Filtration label...
Страница 177: ...Labels and Symbols Page 11 16 42 12 15 29 40 15 13 10 18 39 31 27 24 23 37 38...
Страница 179: ...Chapter12 Technical Reference...
Страница 183: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 12 5 Workstation Weight 170 10kg...
Страница 194: ...Technical Reference Page 12 16 Lateral configuration 1 5m LOHMANN Lateral configuration 1m LOHMANN...
Страница 206: ...Technical Reference Page 12 28 12 11 System Block...
Страница 209: ......
Страница 210: ...www gehealthcare com Imagination at work...