Introduction and Safety
Page 1-4
1.3.
Manufacturer's Responsibilities
GE HUALUN Medical Systems, Co. Ltd. certifies each system and X-Ray source assembly. After-sale
operating practices and safety are the responsibility of the owner/operator.
1.3.1.
X-Ray Equipment Certification
GE HUALUN Medical Systems, Co. Ltd. certifies that when assembled according to manufacturer's
instructions, the X-Ray equipment complies with applicable international standards.
1.3.2.
After-sale Operating and Safety Practices
GE HUALUN Medical Systems, Co. Ltd. assumes no responsibility or liability for personal injury or damage
resulting from misuse of its systems.
1.3.3.
Essential Performance
In order to meet its intended use and comply with regulatory standards, the system provides the following
essential performances:
1. Patient/Image database integrity;
2. Acceptable fluoroscopic image quality;
3. Display & Indication of Last Image Hold (LIH) following termination of X-ray exposure;
4. Maintain X-ray tube voltage accuracy within 10%;
5. Ensure increment/decrement between two settings is within 50% to 150% of indicated change;
6. Maintain X-ray tube current accuracy within 20%;
7. Maintain current time product at +/- (10% + 0.2mAs);
8. The coefficient of variation of MEASURED VALUES of AIR KERMA is not greater than 0.05 for any
combination of LOADING FACTORS;
9. Linearity of AIR KERMA in RADIOGRAPHY is not greater than 0.2;
10. Automatic Brightness Stabilization (ABS) function implementing the Automatic Exposure Rate Control
feature;
11. Provide radiation dose structured report (RDSR) as per IEC/PAS 61910-1:2007.
1.4.
Communication Center Telephone
Numbers
If the system does not operate properly or fails
to respond to the controls as described in your operator’s
manual, call GE HUALUN Medical Systems, Co. Ltd. to request service. The communication center's
telephone and Fax numbers are listed below:
GE HUALUN MEDICAL SYSTEMS CO. Ltd.
No 1 Yong Chang North Road
Beijing Economic-Technological Development Zone
Beijing CHINA.
P.O.: 100176
Содержание Brivo OEC 715
Страница 9: ...Chapter1 Introduction and Safety...
Страница 34: ...Chapter2 System Overview...
Страница 36: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 3 2 2 C Arm Components...
Страница 38: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 2 5 2 3 Workstation Components...
Страница 40: ...Chapter3 Mechanical Positioning...
Страница 52: ...Chapter4 Start Up and Operating Control...
Страница 77: ...Chapter5 Usual Operations...
Страница 108: ...Chapter6 SpecialApplications...
Страница 139: ...Chapter7 Radiographic Film...
Страница 142: ...Chapter8 System Setup...
Страница 149: ...System Setup Page 8 8 Click any mouse button to return to normal screen...
Страница 150: ...Chapter9 Maintenance...
Страница 160: ...Chapter10 Display Messages...
Страница 162: ...Chapter11 Labels and Symbols...
Страница 167: ...Labels and Symbols Page 11 6 18 1 System rating plate indicates manufacture information and input power requirements...
Страница 168: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 11 7 19 1 X ray Generator rating plate Total Filtration label...
Страница 177: ...Labels and Symbols Page 11 16 42 12 15 29 40 15 13 10 18 39 31 27 24 23 37 38...
Страница 179: ...Chapter12 Technical Reference...
Страница 183: ...Brivo OEC 715 785 865 Mobile C Arm X Ray Product Page 12 5 Workstation Weight 170 10kg...
Страница 194: ...Technical Reference Page 12 16 Lateral configuration 1 5m LOHMANN Lateral configuration 1m LOHMANN...
Страница 206: ...Technical Reference Page 12 28 12 11 System Block...
Страница 209: ......
Страница 210: ...www gehealthcare com Imagination at work...