162
|
BHGE
ENABLE (6)
0
0
True - Enables the ALERT
to be reported according to the
configuration.
False - Disables ALERT
reporting.
Not writable for Standard Diagnostics version.
CYCLE_COUNTER_
B_ALERT (35)
Not writable for Standard Diagnostics version.
CYCLE_COUNTER (1)
0
Number of times the travel changes the direction.
Not writable for Standard Diagnostics version.
ALERT_POINT (2)
10000
CYCLE_COUNTER Value, above which the ALERT_POINT
sets the ALERT to True.
Not writable for Standard Diagnostics version.
DEADBAND_AB (3)
0.05-10
1
POSITION change, required to exceed, before the
CYCLE_COUNTER is increased.
Not writable for Standard Diagnostics version.
ALERT (4)
0
0
True if CYCLE_COUNTER is above ALERT_POINT.
Not writable for Standard Diagnostics version.
HISTORIC ALERT (5)
0
0
True if ALERT is true.
Not Changed if ALERT is false.
Not writable for Standard Diagnostics version.
ENABLE (6)
0
0
True - Enables the ALERT
to be reported according to the
configuration.
False - Disables ALERT
reporting.
Not writable for Standard Diagnostics version.
CYCLE_COUNTER_
TREND (36)
The number of times the travel changes direction. The
value increments when the magnitude of the change
exceeds the CYCLE_COUNTER_ALERT.DEADBAND.
No value for Standard Diagnostics version.
CURRENTLY
COLLECTED (1)
0
Cycles for the current 24 hours period.
No value for Standard Diagnostics version.
TODAY(FULL DAY) (2)
0
Cycles for the last full 24 hours period.
No value for Standard Diagnostics version.
LAST_DAY (3)
0
Cycles for the previous full 24 hours period.
No value for Standard Diagnostics version.
PREVIOUS_DAY (4)
0
Cycles for the previous full 24 hours period.
No value for Standard Diagnostics version.
THREE_DAYS_AGO (5)
0
Cycles for the past three days.
No value for Standard Diagnostics version.
Table 31 Transducer Block Parameters (Continued)
Parameter (in bold)
Sub-parameter (Index)
Range
Initial
Value
Mode
Description
Содержание Baker Hughes Masoneilan SVI FF
Страница 12: ...This page intentionally left blank ...
Страница 72: ...This page intentionally left blank ...
Страница 82: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...
Страница 108: ...This page intentionally left blank ...
Страница 198: ...This page intentionally left blank ...
Страница 206: ...This page intentionally left blank ...
Страница 224: ...This page intentionally left blank ...
Страница 228: ...This page intentionally left blank ...
Страница 230: ...This page intentionally left blank ...
Страница 250: ...This page intentionally left blank ...
Страница 262: ...This page intentionally left blank ...
Страница 263: ......