CHAPTER 11: MODBUS MEMORY MAP
MODBUS MEMORY MAP
869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
11-135
80598
0x9E95
Relays
0
0xFFFFFFFF
1
FC198
0
1
80600
0x9E97
Events
0
1
1
FC126
1
1
80601
0x9E98
Targets
0
2
1
FC101
1
1
Close Circuit 3 Monitoring
80606
0x9E9D
Function
0
4
1
FC100A 0
1
80607
0x9E9E
Pickup Delay
0
6000000
1
s
F13
10000
1
80609
0x9EA0
Dropout Delay
0
6000000
1
s
F13
0
1
80611
0x9EA2
Bypass Breaker State
0
1
1
FC126
0
1
80612
0x9EA3
Breaker Status Opened
0
0xFFFFFFFF
1
FC142
0
1
80614
0x9EA5
Block
0
0xFFFFFFFF
1
FC142
0
1
80616
0x9EA7
Relays
0
0xFFFFFFFF
1
FC198
0
1
80618
0x9EA9
Events
0
1
1
FC126
1
1
80619
0x9EAA
Targets
0
2
1
FC101
1
1
Breaker 1 Arcing Current Config
80640
0x9EBF
Function
0
4
1
FC100A 0
1
80642
0x9EC1
Initiation
0
0xFFFFFFFF
1
FC142
0
1
80644
0x9EC3
Delay
0
6000000
1
s
F13
30
1
80646
0x9EC5
Alarm Level
0
50000
1
kA2-cyc
F0
1000
1
80647
0x9EC6
Relays
0
0xFFFFFFFF
1
FC198
0
1
80649
0x9EC8
Block
0
0xFFFFFFFF
1
FC142
0
1
80651
0x9ECA
Events
0
1
1
FC126
1
1
80652
0x9ECB
Targets
0
2
1
FC101
1
1
Breaker 1 Health
80710
0x9F05
Function
0
4
1
FC100A 0
1
80711
0x9F06
Mode
0
1
1
FC277
0
1
80712
0x9F07
Preset Trip Counter
0
100000
1
F10
0
1
80714
0x9F09
Trip Trigger
0
0xFFFFFFFF
1
FC142
0
1
80716
0x9F0B
Close Trigger
0
0xFFFFFFFF
1
FC142
0
1
80718
0x9F0D
Open Status
0
0xFFFFFFFF
1
FC142
0
1
80720
0x9F0F
Close Status
0
0xFFFFFFFF
1
FC142
0
1
80722
0x9F11
Spring Charge Status
0
0xFFFFFFFF
1
FC142
0
1
80724
0x9F13
Trip Time Pickup
0
6000000
1
s
F13
50
1
80726
0x9F15
Close Time Pickup
0
6000000
1
s
F13
50
1
80728
0x9F17
Incomplete Trp/Cls Time 0
6000000
1
s
F13
100
1
80730
0x9F19
Arc Time Pickup
0
6000000
1
s
F13
100
1
80732
0x9F1B
Incomplete Arc Time
0
6000000
1
s
F13
300
1
80734
0x9F1D
Spring Charge Time
Pickup
0
6000000
1
s
F13
15000
1
80736
0x9F1F
Incomplete Charge Time 0
6000000
1
s
F13
45000
1
80738
0x9F21
Arc Energy Pickup
1
100000
1
kA2-cyc
F10
1000
1
80740
0x9F23
Alarm Counter
1
100
1
F0
5
1
80741
0x9F24
Relays
0
0xFFFFFFFF
1
FC198
0
1
80743
0x9F26
Block
0
0xFFFFFFFF
1
FC142
0
1
80745
0x9F28
Events
0
1
1
FC126
1
1
80746
0x9F29
Targets
0
2
1
FC101
1
1
Broken Rotor Bar
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
Содержание 869
Страница 6: ...1 2 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE COMMUNICATIONS CHAPTER 1 INTRODUCTION...
Страница 18: ...2 12 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE ETHERNET PORTS CHAPTER 2 COMMUNICATION PORTS...
Страница 36: ...4 12 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE DNP IMPLEMENTATION CHAPTER 4 DNP 3...
Страница 82: ...8 24 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE THE IEC 61850 CONFIGURATOR CHAPTER 8 IEC 61850...
Страница 84: ...9 2 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE CHAPTER 9 FILE TRANSFER PROTOCOLS...
Страница 94: ...10 10 869 MOTOR PROTECTION SYSTEM COMMUNICATIONS GUIDE MODBUS PROTOCOL CHAPTER 10 MODBUS PROTOCOL...