CHAPTER 7: IEC 61850 PROTOCOL
7.2 IEC 61850 PROFILE FOR F650
GEK-106310-AF
F650 DIGITAL BAY CONTROLLER
7-91
2.3.1.7 hseRDIR
This logical node class is used for sensitive ground directional elements and has 3 instances inside the device.
2.3.1.8 hseRDIR_2
This logical node class is used for sensitive ground directional elements when setting group option is enabled and has 1
instance inside the device. This logical node class is available only for firmware version below 7.50.
RDIR class
Attribute
Name
Attr.
Type
Explanation
M/O
notes
RDIR
Directional Element
Data
Common Logical Node Information
Mod
ModENC
Mode
M
Beh
BehENS
Behaviour
M
Health
HealthENS
Health
M
NamPlt
LPL
Name plate
M
Status Information
Dir
GeneralACD
Direction
M
Op
GeneralACT
Operate
O
Blk
SPS
Block
O
BlkIn
GeneralACT_1
Block Input
O
Settings
RDIREna
SPG
Function
O
ChrAng
FloatASG
Characteristic angle
O
PolOpMod
ING_0
Direction
O
BlkMod
ING_0
Block Logic
O
BlkValV
IntASG
Minimum operating current
O
SnpshtEvEna
SPG
Snapshot events enabled
O
RDIR class
Attribute
Name
Attr.
Type
Explanation
M/O
notes
RDIR
Directional Element
Data
Common Logical Node Information
Mod
ModENC
Mode
M
Beh
BehENS
Behaviour
M
Health
HealthENS
Health
M
NamPlt
LPL
Name plate
M
Status Information
Dir
GeneralACD
Direction
M
Op
GeneralACT
Operate
O
Blk
SPS
Block
O
BlkIn
GeneralACT_1
Block Input
O
Settings
RDIREna
SPG_2
Function
O
ChrAng
FloatASG_2
Characteristic angle
O
PolOpMod
ING_0_2
Direction
O
BlkMod
ING_0_2
Block Logic
O
BlkValV
IntASG_3
Minimum operating current
O
SnpshtEvEna
SPG_2
Snapshot events enabled
O
Содержание F650
Страница 68: ...2 32 F650 DIGITAL BAY CONTROLLER GEK 106310 AF 2 6 EXTERNAL CONNECTIONS CHAPTER 2 PRODUCT DESCRIPTION ...
Страница 406: ...6 58 F650 DIGITAL BAY CONTROLLER GEK 106310 AF 6 5 RECORDS CHAPTER 6 ACTUAL VALUES ...
Страница 660: ...7 254 F650 DIGITAL BAY CONTROLLER GEK 106310 AF 7 3 IEC 61850 CONFIGURATOR CHAPTER 7 IEC 61850 PROTOCOL ...
Страница 734: ...12 6 F650 DIGITAL BAY CONTROLLER GEK 106310 AF 12 4 RELAY CONFIGURATION CHAPTER 12 FREQUENTLY ASKED QUESTIONS ...
Страница 772: ...A 32 F650 DIGITAL BAY CONTROLLER GEK 106310 AF A 1 OPERANDS F650 MODEL FX GX APPENDIX A LOGIC OPERANDS ...
Страница 950: ...c 24 F650 DIGITAL BAY CONTROLLER GEK 106310 AF C 8 ANALOG INPUTS APPENDIX C DNP 3 0 PROTOCOL FOR F650 ...
Страница 994: ...H 2 F650 DIGITAL BAY CONTROLLER GEK 106310 AF APPENDIX H FACTORY DEFAULT LOGIC ...
Страница 995: ...APPENDIX H FACTORY DEFAULT LOGIC GEK 106310 AF F650 DIGITAL BAY CONTROLLER h 3 ...
Страница 996: ...H 4 F650 DIGITAL BAY CONTROLLER GEK 106310 AF APPENDIX H FACTORY DEFAULT LOGIC ...
Страница 998: ...H 6 F650 DIGITAL BAY CONTROLLER GEK 106310 AF APPENDIX H FACTORY DEFAULT LOGIC ...
Страница 999: ...APPENDIX H FACTORY DEFAULT LOGIC GEK 106310 AF F650 DIGITAL BAY CONTROLLER h 7 ...
Страница 1002: ...H 10 F650 DIGITAL BAY CONTROLLER GEK 106310 AF APPENDIX H FACTORY DEFAULT LOGIC ...
Страница 1003: ...APPENDIX H FACTORY DEFAULT LOGIC GEK 106310 AF F650 DIGITAL BAY CONTROLLER h 11 ...
Страница 1004: ...H 12 F650 DIGITAL BAY CONTROLLER GEK 106310 AF APPENDIX H FACTORY DEFAULT LOGIC ...
Страница 1044: ...I 40 F650 DIGITAL BAY CONTROLLER GEK 106310 AF I 2 FACTORY DEFAULT CONFIGURATION APPENDIX I FACTORY DEFAULT CONFIGURATION ...
Страница 1046: ...J 2 F650 DIGITAL BAY CONTROLLER GEK 106310 AF J 1 GE MULTILIN WARRANTY APPENDIX J MISCELLANEOUS ...