Document Number: GAR_IOM_CFABROILER_4603091 rev 00 (08/21/2017)
11
Section 2
Installation
DANGER
,
Installation, adjustments, start-up procedure and
function test of the appliance must be performed by
the manufacturer’s service partners (Factory Authorized
Service Agencies), following all applicable national and
local codes, and health and safety regulations.
Specifications
RATING PLATE LOCATION
The rating plate is affixed to
the lower front of the right
exterior body side panel.
ELECTRICAL SPECIFICATIONS, MODEL: CXPB12 (USA/CANADA, 208V AND 220V)
Voltage
200V
208V
220V
230V
240V
Current L1 (A)
23.2
24.1
23.2
23.4
22.5
Current L2 (A)
27.1
28.2
26.6
26.5
24.9
Current L3 (A)
22.2
23.1
22.0
22.0
20.9
Total Power(kW)
8.3
9.0
8.8
9.2
9.0
NOTE: Wiring diagram is supplied with each unit.
Cable and Plug:
Provided with each unit, a 5-foot (1.5m) long power supply cord with an integral (NEMA 15-50P) plug.
CLEARANCE REQUIREMENTS
Minimum Clearance to Non-Combustible Walls / Floor
Minimum Clearance to Combustible Walls / Floor
(See Safety Warning Statement below)
Sides
Rear
Sides
Rear
0”
0”
NOT ALLOWED
NOT ALLOWED
,
CAUTION
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE INSTALLED IN NON-COMBUSTIBLE SURROUNDINGS ONLY
,
with no combustible material within 18” (457 mm) of the sides, front, or rear of the appliance or within 40” (1 m) above
the appliance. The appliance is to be mounted on floors of noncombustible construction with noncombustible flooring
and surface finish and with no combustible material against the underside, or on noncombustible slabs or arches have no
combustible material against the underside. Such construction shall in all cases extend not less than 12” (305 mm) beyond
the equipment on all sides.