Confirm Secondary Time Window (default = 60 minutes)
This time window may be programmed between 1 and 120 minutes we would suggest
a time between 30 and 60 minutes but should typically be the same time as the
confirm time window. This option affects zones that have been allocated as secondary
zones only. For functionality please refer to Secondary Zones Below.
ET (Exit Terminator) Mode (default = Set)
If ET Mode = Set then the exit terminator zone will terminate the exit procedure.
If ET Mode = Door Lock and the ET zone (door lock) is operated on entry then all
confirmed alarms will be disabled.
See 6.4.3 DD243:2002 Unlocking the initial entry door disables all means of
conformation.
Bell Mode (default = Unconfirmed)
This option controls the bells fitted to the system, options are confirmed or un-
confirmed.
If Bell Trigger = Confirmed then Bell will only trigger with a confirmed alarm.
If Bell Trigger = Unconfirmed then Bell will trigger with un-confirmed alarms.
This feature is not mandatory for DD243
Strobe Mode (default = Unconfirmed)
This option controls the Strobe(s) fitted to the system, options are confirmed or un-
confirmed.
If Strobe Trigger = Confirmed then Strobe will only trigger with a confirmed alarm.
If Strobe Trigger = Unconfirmed then Strobe will trigger with un-confirmed alarms.
This gives the ability to show to the keyholder from outside the premises that a
previously unconfirmed alarm has is now confirmed.
This feature is not mandatory for DD243
Confirmed Start Delay (default = 000m)
May be programmed between 0 & 120 minutes (default 0).
If programmed to anything other than 0 the panel cannot send confirmed signals until
the time programmed has expired. This time starts when the system has set and will
prevent confirmed alarms being generated in situations when a person has been
accidentally locked in the building.
This feature is not mandatory for DD243
Ace Battery monitor (default = On)
Options are On or Off. This option allows for the use of new control panel boards with
V5.1 or later software to be used with earlier keypads. If older non DD243 compliant
type keypads are used with V5.1 or later this option should programmed to Off. It is a
requirement of DD243 2002 that when using ACE Low Battery is reported to the end
user if the system is set using ACE.
See A.1 DD243:2002 Portable ACE used for setting and unsetting.
Comms Restore
For DD243 systems this option should be on (default setting On). With the option On
the alarm channel will be restored at the end of the time programmed in Confirmed
Time Window.
Appendix 1
GardTec
872
872.qxd 05/11/2003 15:01 Page 92
Содержание 872
Страница 108: ...Extending RKP Wiring to 500mtrs Page 107 GardTec 872 Appendix 1 872 qxd 05 11 2003 15 01 Page 107...
Страница 109: ...Extending Expander Wiring to 500mtrs Page 108 Appendix 1 GardTec 872 872 qxd 05 11 2003 15 01 Page 108...
Страница 111: ...Page 110 Appendix 1 GardTec 872 872 qxd 05 11 2003 15 01 Page 110...