![GARDTEC 872 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/gardtec/872/872_installation-instructions-manual_3561995050.webp)
Page
49
Printer Connection
The GardTec
872
has an RS232 port that may be connected to a standard serial
printer, to facilitate this two printer leads are available from GardTec Ltd.
Printer Cable No. 1
Part No 01-091
Connects from PCB direct to printer
Printer Cable No. 2A
Part No 01-092
Connects from PCB to chassis mounting
DIN socket (to be mounted on panel
case).
Printer Cable No. 2B
Part No 01-093
DIN plug to printer
The printer should be capable of being set to the following:-
Baud Rate
1200
Data Bits
8
Parity
None
Stop Bits
4
Carriage Return
None
Note:
The printer should have its own power supply. Under no circumstances
should the power for the printer be drawn from the control panel.
The printer may be used in one of three modes:-
1)
For printing the Event Log (user or engineer function). Pressing 1 whilst
viewing the Event Log will start the printer (refer to user manual for more
details).
2)
For printing the Program Review (engineer function). Pressing 1 whilst in the
engineer option Program Review will start the printer.
3)
For Real Time Printing. When Real Time Printing is programmed to ON each
event that is written to the log will also be sent to the printer.
This option needs to be set ON from within the engineer programming mode
(option 96) and may be overridden by the user by using the online / offline
function on the printer.
Two suggested Printers are currently available, one from RS Components and one
from Farnell Electronics.
Descriptions and Part Number correct at time of going to
press.
GardTec
872
Wiring Connections
RS Components
Description
Part No.
24 col/2.5 lps printer
244-632
Power Adaptor
244-654
2 Rolls + 1 Ribbon
202-981
Farnell Electronics
Description
Part No.
Serial Printer 2.5 lps
255-701
Battery Charger UK
231-540
Paper Roll 15m
177-306
Paper Roll 30m
231-952
Ribbon
308-213