Zone Type Terminology (Zone Types)
Each zone has a default type that may be re-programmed. Below is an explanation of
the terminology used for zone types.
12 Hour
Zone active when Control Panel is Set.
Access
Will allow to pass through on exit.
Will allow to pass through on entry only if E/E is opened first.
24 Hour
Internal Sounder if Unset.
Full alarm if Set.
Remains active in Engineer Programming Mode.
Entry/Exit (or E/E)
Zone used as last exit point (will terminate exit time if setting mode is set to
E/E or Time+E/E).
Will start E/E time if opened when Control Panel is Set
Part E/E
As Access if Control Panel is Full Set
As Entry/Exit if Control Panel is Part Set
Panic
24Hour Personal Attack (or Panic Attack). Active if Control Panel is Set,
Unset or in Engineer Programming Mode . May only be tested via Engineer
code if programmed as testable.
Alert
Internal Sounder Only, Recorded to Log when Unset
Recorded to Log when SET
Fire
Will give Fire alarm when activated (pulsed sounders) with Control Panel Set
or Unset.
Remains active in Engineer Programming Mode.
ET
Exit terminator. Used for final setting of the system. Exit Mode must be
programmed for ET or Time + ET.
Monitor
Will write to the log once only in any one set or unset unless chime is
allocated then all activations are written to the log.
KSW Bat
When used zone should be connected to the trouble/status output of third
party radio equipment that is capable of giving a low battery signal.
Line Fault
When used acts as a Line Fault input to the control panel.
GardTec
872
Areas, Zones & Output Types