Communications Outputs
. These are available on the following terminals
D1
D2
D3 (PA terminal)
D4 (12Hr terminal)
Digicom Channels (when used with GardTec ProDigi or Digi / Modem)
Below is given a list of Output Types with a brief description of the option.
Off
Output not used
Zone 24Hr
Will activate when a 24Hr zone is triggered
Gen Tamper
Will activate with bell / control / keypad / zex tampers
Alert
Will activate when an alert zone is triggered
Fire
Will activate when a fire zone is triggered
Part Set
Will activate when the system is part set or when a zone is removed (omitted)
Open / Close
Will activate when panel set or unset
Panic
Will activate when a panic zone is triggered will also activate when a duress code is
entered
Alarm
Will activate when panel is in alarm and will reset when the panel auto rearms or when
the panel is reset
Page
59
GardTec
872
Areas, Zones & Output Types
872.qxd 05/11/2003 15:01 Page 59