IMPORT
IMPORT
ANT!
ANT!
Input:
/-10% ~50Hz 125mA Max. 35W Max
Nominal Temp Range: 0 - 50°C
GardTec
872
Metal Versions
For Indoor Use Only
GardTec
872
Plastic Versions
For Indoor Use Only
This equipment is intended only for use as a Security Alarm Control Panel. Adequate ventilation
away from heat and humidity must be provided. The unit must be fixed securely to a non-
flammable surface using suitable fixings.
All mains wiring must be to BS7671 (1992) IEEE wiring regulations (or appropriate international
regulatory standards). See Mains Supply Connection section within this manual for more
detailed instructions.
All wiring must be protected from sharp or jagged edges.
All Low voltage (alarm) wiring must be to the appropriate international regulatory standards
and comply to good wiring practice. It should not be possible for the Low Voltage wiring to
touch the Mains wiring.
Replacement fuses should be of the same type and rating conforming to IEC 127.
The maximum current draw from the unit for all output combinations
must not exceed 1Amp.
The unit is intended for use with a suitable re-chargeable lead acid battery permanently
connected to the appropriate terminals.
All documentation and manuals must be thoroughly read by suitably qualified installation
personnel prior to installation.
The unit has no user serviceable parts inside. Internal access should only be by suitably quali-
fied personnel.
GardTec
872
Metal Versions
The unit must be Earthed.
It is the responsibility of the installation engineer to ensure that the
earth connection to the unit lid is good on completion of the installation or after service.
GardTec
872
Plastic Versions
Provision is provided for an earth connection within the mains input connector block, this con-
nection is for protection of the wiring only and is not functional for the unit.
GardTec
872