![GARDTEC 872 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/gardtec/872/872_installation-instructions-manual_3561995075.webp)
Page
74
7 S
PECIFICATION
& R
ECORDS
GardTec
872
Control Panel Specification
Power Input
230V a.c +/- 10% @ 50Hz
Max Loop Resistance
2K (not with E.O.L)
Loop Delay Time
600 milliseconds
FUSES
Bell
1A Quick Blow
R.K.P
500mA Quick Blow
Aux
1A Anti-surge
Gard
400mA Quick Blow
Mains
125mA Anti-surge
Low Voltage Output
13.8 Regulated
Battery Sizes
12V 1.2A, 2.0A, 3.0A, 7.0A
Construction
3mm Polycarbonate
or
1.2mm Mild Steel
Complies With
BS 4737 Parts 1 & 2
CE tested
Conforms with
EMC Directive 89/336/EEC & LVD Directive 73/23/EEC
Number Of Zones
(Standard)
8 (4 Wire), 16 (E.O.L or 2 Wire)
Expandable To
80 (4 Wire), 144 (EOL or 2 Wire)
Expansion Type
Expander Cards with 4 (4 Wire) per card
Zones or 8 (E.O.L or 2 Wire) per card
Zones Per Card
1 Radio Expander may be fitted allowing 2 Receivers may
be fitted in place of Expander 8 &16 (if required)
or
ID Expander Cards (Max2)
30 ID zones per Expander
(Panel zones as normal)
Radio Expander cannot be used with ID
872.qxd 05/11/2003 15:01 Page 74