13-9-666 Page 66
SYMPTOM
POSSIBLE CAUSE
REMEDY
Compressor starts too
slowly
1.
Wye Delta switch time set
too long.
1.
Contact your Champion
distributor.
2.
Minimum Pressure/Check
Valve is faulty.
2.
Repair or replace.
3.
Supply voltage is too low.
3.
Check the supply voltage.
Compressor is low on
delivery and pressure
1.
Restricted air filter.
1.
Clean or replace filter.
2.
Sticking inlet valve.
2.
Inspect and clean inlet
valve.
3.
Minimum pressure valve
stuck closed.
3.
Replace valve.
4.
Leaks in the compressed
air system.
4.
Check for leaks, fix any
leaks found.
5.
Aftercooler is frozen
5.
Thaw out. This machine
cannot operate in
temperatures below 32
°
F
(0
°
C).
6.
Unload pressure adjusted
too low.
6.
Adjust the unload
pressure. See Manual
13-9-653.
Excessive oil
consumption
1.
Oil carryover through
lines.
1.
See “Oil Carryover”, in this
section.
2.
Oil leaks at all fittings and
gaskets.
2.
Tighten or replace fittings
or gaskets.
3.
Shaft seal leaking.
3.
Replace shaft seal.
High discharge air
temperature
1.
Thermostatic mixing valve
stuck open.
1.
Repair or replace valve.
2.
Dirty or clogged cooler
face.
2.
Clean cooler.
3.
Insufficient cooling air flow
3.
Provide unrestricted
supply of cooling air.
4.
Clogged oil filter or cooler
(interior)
4.
Replace filter or clear
cooler.
5.
Low compressor oil.
5.
Add oil to proper level.
Содержание ELECTRA-SAVER EAQ99Q
Страница 10: ...13 9 666 Page 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 11: ...13 9 666 Page 4 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 13: ...13 9 666 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 14: ...13 9 666 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 43: ...13 9 666 Page 36 Figure 4 13 WIRING DIAGRAM WYE DELTA EBQ EBU UNITS 300EDM546 A Ref Drawing...
Страница 44: ...13 9 666 Page 37 Figure 4 14 WIRING DIAGRAM FULL VOLTAGE EBQ EBU UNITS...
Страница 45: ...13 9 666 Page 38 Figure 4 15 WIRING DIAGRAM WYE DELTA EAQ EAU UNITS ONLY 301EAQ546 B Ref Drawing...
Страница 46: ...13 9 666 Page 39 Figure 4 16 WIRING DIAGRAM FULL VOLTAGE EAQ EAU UNITS ONLY 303EAQ546 Ref Drawing...
Страница 50: ...13 9 666 Page 43 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...