13-9-666 Page 63
SECTION 8
MAINTENANCE SCHEDULE
SERVICE CHECK LIST
Air Filter
- Operating conditions determine frequency of service. If the “CHANGE AIR FILTER” message
is displayed, air filter requires servicing or changing. See “Air Filter", Section 6.
Oil Separator
- Operating conditions determine frequency of service. If the “CHANGE SEPARATOR”
message is displayed, the oil separator element requires changing. See “Compressor Oil Separator” in
Section 5, for further details.
Motor Lubrication
- Refer to Section 2, and Maintenance Schedule Chart, page 64.
Every 8 Hours Operation
1.
Check the reservoir oil level - add oil if required. See Section 5. If oil consumption is high, refer to
“Excessive Oil Consumption, page 66. DO NOT MIX LUBRICANTS.
2.
Observe if the unit loads and unloads properly.
3.
Check discharge pressure and temperature.
4.
Check Panel LED’s for advisories.
Every 125 Hours Operation
1.
Check for dirt accumulation on oil/aftercooler core faces and the cooling fan. If cleaning is required,
clean the exterior fin surfaces of the cores by blowing compressed air carrying a nonflammable
safety solvent in a direction opposite that of the cooling fan air flow. This cleaning operation will
keep the exterior cooling surfaces clean and ensure effective heat dissipation.
Every 1000 Hours Operation
1.
Change the oil filter element.
Every 8000 Hours Operation
1.
Change the compressor lubricant. UNDER ADVERSE CONDITIONS, CHANGE MORE
FREQUENTLY (refer to “Oil Change Interval”, page 48). Flush system if required.
Every Year
1.
Check the relief valve for proper operation. See Section 4.
2.
Check shutdowns for proper operation.
Содержание ELECTRA-SAVER EAQ99Q
Страница 10: ...13 9 666 Page 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 11: ...13 9 666 Page 4 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 13: ...13 9 666 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 14: ...13 9 666 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 43: ...13 9 666 Page 36 Figure 4 13 WIRING DIAGRAM WYE DELTA EBQ EBU UNITS 300EDM546 A Ref Drawing...
Страница 44: ...13 9 666 Page 37 Figure 4 14 WIRING DIAGRAM FULL VOLTAGE EBQ EBU UNITS...
Страница 45: ...13 9 666 Page 38 Figure 4 15 WIRING DIAGRAM WYE DELTA EAQ EAU UNITS ONLY 301EAQ546 B Ref Drawing...
Страница 46: ...13 9 666 Page 39 Figure 4 16 WIRING DIAGRAM FULL VOLTAGE EAQ EAU UNITS ONLY 303EAQ546 Ref Drawing...
Страница 50: ...13 9 666 Page 43 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...