13-9-666 Page 50
FILLING OIL RESERVOIR
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
1.
Be sure the unit is completely off and that no air pressure is in the oil reservoir.
2.
Disconnect, lockout and tagout the power supply to the starter.
3.
Wipe away all dirt around the oil filler plug.
4.
Remove the oil filler plug and add oil as required to return the oil level to the center of the green
range on the gauge.
5.
Install the oil filler plug and operate the unit for about a minute allowing oil to fill all areas of the
system. Check for leaks.
6.
Shut down unit, allowing the oil to settle, and be certain all pressure is relieved.
7.
Add oil, if necessary, to bring level to the center of the green range on the gauge.
On unloaded operation and after shutdown some oil will drain back into the oil reservoir and the oil level
gauge will read “FULL.” DO NOT DRAIN OIL TO CORRECT. On the next start, oil will again fill the
system and the gauge will indicate operating at the proper level. DO NOT OVERFILL as oil carryover will
result. The quantity of oil required to raise the oil level from “ADD” to “FULL” is shown in Figure 5-8.
Repeated addition of oil between changes may indicate excessive oil carryover and should be
investigated.
Use only CLEAN containers and funnels so no dirt enters the reservoir. Provide for clean storage of oils.
Changing the oil will be of little benefit if done in a careless manner.
CAUTION
Excessive oil carryover can damage equipment. Never fill oil reservoir above
the "FULL" marker.
125, 150 & 200 HP
Refill Capacity for Normal Oil Change
21.0 U.S. Gallons (79.5 Liters)
Red to Yellow Range
3.5 U.S. Gallons (13.25 Liters)
Figure 5-8 – APPROXIMATE OIL SYSTEM CAPACITIES
Содержание ELECTRA-SAVER EAQ99Q
Страница 10: ...13 9 666 Page 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 11: ...13 9 666 Page 4 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 13: ...13 9 666 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 14: ...13 9 666 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 43: ...13 9 666 Page 36 Figure 4 13 WIRING DIAGRAM WYE DELTA EBQ EBU UNITS 300EDM546 A Ref Drawing...
Страница 44: ...13 9 666 Page 37 Figure 4 14 WIRING DIAGRAM FULL VOLTAGE EBQ EBU UNITS...
Страница 45: ...13 9 666 Page 38 Figure 4 15 WIRING DIAGRAM WYE DELTA EAQ EAU UNITS ONLY 301EAQ546 B Ref Drawing...
Страница 46: ...13 9 666 Page 39 Figure 4 16 WIRING DIAGRAM FULL VOLTAGE EAQ EAU UNITS ONLY 303EAQ546 Ref Drawing...
Страница 50: ...13 9 666 Page 43 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...