13-9-666 Page 8
SECTION 2
INSTALLATION
GENERAL
- On receipt of the unit, check for any damage that may have been incurred during transit.
Report any damage or missing parts as soon as possible.
CAUTION
Do not electric weld on the compressor or base; bearings can be damaged by
passage of current.
LIFTING UNIT
- Proper lifting and/or transporting methods must be used to prevent damage. Lifting slots
are provided in the base for towmotor use. The unit may also be moved into location by rolling on bar.
CAUTION
Lift compressor unit by base only. Do not use other places such as motor,
compressor or discharge manifold piping as lifting points.
DANGER
The eyebolts or lugs provided on the motor are for lifting the motor only and
should not be used to lift any additional weight. All eyebolts must be securely
tightened. When lifting the motor, the lifting angle must not exceed 15 degrees.
Failure to observe this warning may result in damage to equipment or personal
injury.
LOCATION
- The compressor should be installed, whenever possible, in a clean, well-lighted, well-
ventilated area with ample space all around for maintenance. Select a location that provides a cool,
clean, dry source of air. In some cases it may be necessary to install the air filter at some distance from
the compressor to obtain proper air supply.
Both the air-cooled and water-cooled units require cooling air as well as air to the compressor inlet.
Proper ventilation MUST be provided; hot air must be exhausted from the compressor operating area. A
typical inlet-outlet air flow arrangement is shown in Figure 2-1.
Figure 2-1 – TYPICAL COMPRESSOR ROOM
Содержание ELECTRA-SAVER EAQ99Q
Страница 10: ...13 9 666 Page 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 11: ...13 9 666 Page 4 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 13: ...13 9 666 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 14: ...13 9 666 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 43: ...13 9 666 Page 36 Figure 4 13 WIRING DIAGRAM WYE DELTA EBQ EBU UNITS 300EDM546 A Ref Drawing...
Страница 44: ...13 9 666 Page 37 Figure 4 14 WIRING DIAGRAM FULL VOLTAGE EBQ EBU UNITS...
Страница 45: ...13 9 666 Page 38 Figure 4 15 WIRING DIAGRAM WYE DELTA EAQ EAU UNITS ONLY 301EAQ546 B Ref Drawing...
Страница 46: ...13 9 666 Page 39 Figure 4 16 WIRING DIAGRAM FULL VOLTAGE EAQ EAU UNITS ONLY 303EAQ546 Ref Drawing...
Страница 50: ...13 9 666 Page 43 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...