PULSE Installation, Commissioning and Servicing Manual - Revision 19
Grade 91
The flow rate for Grade 91 can be tested by using
Base Valve 5
and
Out
Valve 4
.
With a normal delivery, the Base Valve will be open to 100% and the Out Valve will adjust
the flow rate to meet the target flow defined in the Flow Control settings.
Diesel
The valve percentage and flow rates of
Valve 6
(Diesel) can be tested and adjusted as on
a standard unit.
Grade 95
The flow rate for Grade 95 is tested using
Motors 1
and
2
with
Out Valve 3 and
Base
Valves 5
and
1
simultaneously.
Flow rate settings adjusted in a stack test for Grade 98 or Grade 91 will not affect the
normal delivery of Grade 95.
95
91
98
2
5
Out
Valves
Base
Valves
Motors
2
1