15.12 Start-Up Delay - STARTDEL
This function sets the delay before deliveries can start. Start-up delay is set to 0.0 by
default. The delay should be entered in tenth of a second increments with a maximum
setting of 30.0 seconds
5.0
CPL Window
CPL Window
5.0
CPL Window
6.5
CPL Window
6.5
38
CPL Window
C
STARTDEL
FP7
L
C
SD FP7
HOSE 1
L
C
SD FP7
HOSE 2
L
C
SD FP7
HOSE 2*
L
C
SD FP7
HOSE 2
L
C
FLOWCTRL
FP7
L
C
FC FP7
H1 OFF
L
The Dollars display shows
STARTDEL
and the Litres display
shows
FP(X)
, where (X) represents the fuelpoint number.
Use the cursor keys
4
and
6
to navigate left and right
through the different fuelpoints.
Press
F
to view the start-up delay for each hose of the
selected fuelpoint. Press
4
or
6
to scroll to other hoses.
The Dollars display shows
SD FP(X)
, where (X) represents the
fuelpoint number, and the Litres display shows
Hose (Y)
, where
(Y) represents the hose number. The start-up delay for the
selected hose is displayed in the first available CPL window.
Press
F
to change the start-up delay of the selected hose,
an asterisk next to the hose number indicates editing mode.
In this mode, the keypad becomes numerical entry, so
65
is
entered as
65
with the decimal place shown on screen.
Press
F
to confirm change or
to cancel .
Press
4
or
6
to scroll to other hoses or press
to return
to
STARTDEL
to select another fuelpoint.
15.13 Flow Control - FLOWCTRL
This function can enable or disable the flow control management as well as edit the target
flow rate for each hose on each fuelpoint. Changes will be saved to the config.
With Flow Control enabled, the dispenser will control the flow rate by either limiting the
flow to the target flow rate set (by default 38 L/min for a standard hose) or increasing the
flow to meet this value.
The target flow rate is recommended to be set at
38 L/min
for standard hoses and nozzles.
VR hoses/nozzles should
NOT
be set to more than
38 L/min
.
High flow hoses must
NOT
be set to more than
80 L/min
.
The Dollars display shows
FLOWCTRL
and the Litres display
shows
FP(X)
, where (X) represents the fuelpoint number.
Use the cursor keys
4
and
6
to navigate through the
different fuelpoints.
Press
F
to enter the flow control menu for the selected Fuel
Point.
Press
4
or
6
to scroll through hoses. The Dollars display
shows
FC FP(X)
, where (X) represents the fuelpoint number,
and the Litres display shows
H(Y) ON
(or
OFF
), where (Y)
represents the hose number. The maximum flow rate for the
selected hose is displayed in the first available CPL window.
$
$
$
$
$
$
$
Version 1.20