PULSE Installation, Commissioning and Servicing Manual - Revision 19
Version 1.20
16.4 Calibration
The procedure for calibrating the various grades is as follows:
Grade 1 98
Normal procedure.
Grade 2 95
No calibration is possible.*
Grade 3 91
Normal procedure.
Grade 4 Diesel
Normal procedure.
*If Grade 2 is out of acceptable tolerance, recalibrate Grades 1 and 3.
16.5 Flow Control - FLOWCTRL
All target flow rates can be adjusted.
Grade 1 98
H1
Leave on. .
Grade 2 95
H4
Leave off.
Grade 3 91
H2
Leave on.
Grade 4 Diesel
H3
Leave on.
16.6 Grade Priority - MAPPING
Must be set to
1342
.
Note:
Will display 134256.
16.7 Setting Hoses Active/Inactive - HOSE
This function allows the hoses to be set to active (
ON
) or inactive (
OFF
)
Grade 1 98
H1
Grade 2 95
H4
Grade 3 91
H2
Grade 4 Diesel
H3
17
RATIO ERROR
When a blended delivery falls outside the tolerance, the delivery will be stopped and
RATIO ERROR
will display on the screen. The tolerance ensures the blended grade does
not fall below 95 Octane.
The error is cleared by lifting and replacing a nozzle on that side of the dispenser.
Should three consecutive blended deliveries stop with a ratio error, the blended hose is
disabled and cannot be used until it is reset in service mode by service personnel.
A ratio error can only occur after a minimum delivery of 2 litres.
A hose made inactive due to ratio error will not respond to nozzle lift and no price will be
present in the price window.
To re-activate the blended hose, enter the service mode and scroll to the
HOSE
setting for
the particular grade.
0
beside the hose number shows it is inactive.
Press
5
to re-activate the hose and the
0
will change to
1
Ratio Error is most commonly due to an obstructed base valve.
38
C
FLOWCTRL
FP7
L
C
FC FP7
H4 OFF
L
$
$
MAPPING
1342
56
L
C
HOSE
H1 ON
L
$