SER
VICING
98
PULSE Installation, Commissioning and Servicing Manual - Revision 19
Press
5
to toggle the flow control ON or OFF. Press
F
to change
the target flow rate of the selected hose, an asterisk next to the hose
number indicates editing mode. In this mode, the keypad becomes
numerical entry.
Enter the new maximum flow rate and press
F
to confirm the change.
to cancel
Press
4
or
6
to scroll to other hoses or press
to return to
FLOWCTRL
to select another fuelpoint.
C
C
D
DATE
12.06.16
L
C
D
C
D
C
FC FP7
H2* ON
L
C
H2 ON
L
C
L
FC FP7
FLOWCTRL
FP8
TIME
12.06.29
L
TIME*
12.06.29
L
DATE*
12.06.16
L
15.14 View/Set Time - TIME
Setting the date and time ensures that the time stamps on Error Logs are correct.
The display will show
TIME
in the Dollars display and the current Central Controller time
in the Litres display.
To set the time, press
f
. The Dollars display shows
TIME*
.
An asterisk (
*
) after the function name indicates that the system
is in edit mode.
Enter the time (HHMMSS). Note that if the time is entered using all six
figures, there is no need to confirm entry, i.e. the system automatically
accepts and acts on the entered time. At any time press
f
to confirm
the new time entered.
The Dollars display shows
TIME
(without the asterisk) to indicate that the
UI is back in ‘view’ mode.
The Dollars display shows
DATE
(without the asterisk) to indicate that the UI is back in
‘view’ mode.
Gallagher advise the checking of the date and time when obtaining dispenser logs.
Should either be incorrect, make a note to be included with the logs. This will assist
in finding the events under investigation.
$
$
$
$
$
$
$
15.15 View/Set Date - DATE
Setting the date and time ensures that the time stamps on Error Logs are correct.
The display will show
DATE
in the Dollars display and the current Central
Controller date in the Litres display.
To set the date, press
f
. The Dollars display shows
DATE*
An asterisk (
*
) after the function name indicates that the system
is in edit mode.
Enter the date (DDMMYY). Note that if the date is entered using all six
figures, there is no need to confirm entry, i.e. the system automatically
accepts and acts on the entered date. At any time, press
f
to confirm
the new date entered.
Version 1.20