INST
ALLA
TION
28
PULSE Installation, Commissioning and Servicing Manual - Revision 19
7
CORRECT FITTING OF HOSES TO HI-ARM
As shown in the illustration below, a sufficient length of hose (arrowed) must be provided
between where the hose exits the pump and the hose clamp.
This will avoid any crimping of the hose which would restrict product flow and possibly
lead to hose damage.
The clamp should be attached slightly past the 12 o’clock position towards the delivery
side of the hose.
Once correctly installed the hose may be pulled in any direction and not become tight.
Figure 5�
Correct Method of Fitting Hoses to High-Arm
6
NOZZLE SWITCH CONNECTION
Make sure that the switch connector is correctly plugged in with the hook fully engaged
under the stop.
A cable tie can be used to prevent movement causing the switch to disconnect.
incorrect
correct
cable tied
Figure 4�
Correct Nozzle Switch Connection
kinking of hose
correct positioning of clamp
around anti-kink sleeve
incorrect and correct fitting of hose