PULSE Installation, Commissioning and Servicing Manual - Revision 19
11. Unplug the newly addressed LPG meter inside the head.
12. Repeat from step 2 for any remaining LPG meters to be addressed, only plugging in
the meter currently being addressed.
13. Once all meters have been addressed, unplug all LPG meters inside the head, then
plug them all back in.
14. Wait 30 seconds for the meter boot process to complete.
Indicator LED is red when booting, green when ready.
15. Exit service mode.
16. Turn pump off, wait 30 seconds, and repower pump.
17 IMPORTANT:
Fluid must now be run in a stack test for all meters being addressed.
18. For all LPG meters, set meter security switches (dip 1) to
ON
, check all meter
switches are set to correct positions for both meters.
19. For all LPG meters, replace large meter cover and install new wire/lead tamper
seals unless performing a calibration next.
Notes:
i.
LPG meter addressing must occur immediately after resetting that meter. A meter
should not be repowered between the reset and addressing.
ii. Only one meter address may be set at a time. All other LPG meters must be
disconnected or addressing will fail.
iii. LPG meters MUST be repowered after setting a meter address in order to save the
new address properly. This is normally done by unplugging and reconnecting meter
cables inside the head.
iv. Pump must be repowered after all meter addressing has been completed in order
for LPG deliveries to function correctly.
v. The LED indicator is between the dipswitches and plug connector and is usually not
directly visible. A key is useful to reflect the light.
3
4
1
2
Service
Connector
Status
LED
=
V
olum
e
Correction
OFF
=
V
olum
e
Correctio
n
ON
=
Fact
.
Sett.
All
Parameter
=
Fact
.
Sett.
Com.
Para.
=
Security
ON
=
Security
OFF
Service
Connector
Status
LED
=
V
olume
Correctio
n
OFF
=
V
olum
e
Correction
ON
=
Fact
.
Sett
.
All
Para
met
er
=
Fact
.
Sett
.
Com
.
Para
.
=
Security
ON
=
Security
OFF
3
4
1
2
ON
OFF