63
GalStar
Instruction 1.0
4. Advanced Operation
•
Elmnt. Value:
Shows the value of the element when conditioning according to a value element
(a sensor, water meter etc.).
•
Log.Cond.Delay-Sec:
When the condition is not working it shows the delay time as programmed.
During waiting time it counts down.
Logic Condition Programming (452):
(Programmable, Element Screen) Press “Main” ”>”Gnrl
Elmnts”>“Logic Cond.”>”Cond Prog” to access:
Screen Explanation:
•
Start/End Time
(2 parameters)
:
The condition will be active during this range of time if entered.
If not entered the condition will act when the condition is “true”.
Condition Definition (the “If” clause):
•
Cond. Element *:
The element according to which the condition is activated (the “if” clause”).
The options are:
N.Active, Input
– conditioned input (On/Off)
, Valve
(On/Off)
, Program
– Irrigation
Program (On/Off)
, Frt.Pmp
(On/Off)
, Aux Out
(On/Off)
, Sensor
(Value)
, FiltGrp
(On/Off)
,
Commun.
– Other controller’s parameter (On/Off, Value – depending on the transferred variable)
,
Wtrt.Mtr
– the flow rate of the water meter (Value)
, Gen.Mtr
– the flow rate (Value)
.
•
Head of Elmnt No.:
Enter the number of the irrigation head containing the element (head 1 or
head 2). For general elements that do not belong to an irrigation head enter zero.
•
Element No.:
The number of the element.
•
Condition Type *:
The options are:
o
Off:
The condition status is “On” when the element is “Off”.
o
On:
The condition status is “On” when the element is “On”.
o
Below:
(For value elements) the condition for operation when the value of the element is
below the “Operation Value” (the next parameter).