4. Advanced Operation
•
Information About The Water Meter Functioning:
The parameters
Uncontrolled. Water,
No Water Pulse, Pulse Fault Delay
are shown. (See explanation in the “Constant” section).
•
Irrig Program A-E:
These parameters show the number of the program using the water meter.
up to 5 programs can work simultaneously with the same water meter
Water Counter Setup (1823):
Press “WtrCnt Const” in the “Water Counter Status -182” to access:
Screen Explanation:
(Programmable, Element Screen)
•
Count. Slot/Port & Count. Pulse Size
(2 parameters)
:
For information only. See “Setup” chapter.
•
Reset Flow - Mnt.:
The number of minutes from the last pulse after which the flow rate is reset.
•
No Pulse Time-Sec.:
The maximum time difference between two pulses of the water meter.
After this time has passed an alarm is issued.
•
Max.Trial Before Flt:
•
Fault Reaction * (Idle, Pause, Alarm, Fault)
•
Leakage Water M3 (Gallon):
(Uncontrolled water) – water pulses received from the water
meter when all of the valves using this water meter are closed. This number is reset at midnight and
at the beginning of irrigation.
Head No.2 Definition:
All of the above explanations concerning “Head 1” apply to “Head 2” too.
The numbers of the screens are identical except that they start with the digit 2 instead of 1.