4. Advanced Operation
Manual Opening Time (164):
It is possible to open the main valve for a range of dates and a range
of hours for each day. Press “Manual Time” in the “Head Constants – 16” screen to access the “Manual
Opening time” screen (164) in which you can enter: Start/End date and Start/End time. The date range
must be defined. If the hour is left zero it will stay open all of the time during the date range.
Head Fault Setup (165):
Press “Fault Setup” in the “Head Constant” screen to access the “Head
Fault Setup – 165” screen. The parameters in this screen are:
•
Flush Fail React (Idle, Alarm, Pause, Fault):
Filter flush reaction fault. See screen 161.
•
Auto Reset (Yes/No):
See “Auto Reset” explanation in the “Alarm Setup” chapter.
Other Elements:
An access menu for programming filter flushing and water counters information.
Flush Status (181):
This is the first screen of the filter flushing section. Press “Main”>”Gnrl.
Elements”>”Flush” in order to access:
Screen Explanation:
(Information only)
•
Group Status:
The options are:
o
N.Active:
o
Ready:
The flushing system is properly defined and ready for operation when there is no irrigation.
o
Waiting:
The flushing system is between flushes.
o
Sustain:
It is possible to install a sustaining valve after the filter group in order to sustain
the pressure for better flushing. The sustaining valve only sustains during flushing.
o
Flush:
The system is currently flushing.
o
Fault:
The system is in a “Fault”.
o
UnitOut:
Definition error of one of the filter outputs