4. Advanced Operation
•
Next Cond. Cycle Min:
The time remaining to the next possible operation. When working with
conditions and program time together the condition will be active only within the time range. At the
beginning of operation this parameter is the same as “Cyclic Interval” from the “Irrigation Program”.
It then starts counting down. The condition can only work if this parameter is zero.
•
Start Log Cond, Oper. Log. Cond, Pause Log Cond., End Log Cond., Fault Log Cond.:
The status of the logical condition. The options are:
Void, Defined, On.
Last Irrigation (1211):
Press “Last Irrigation” in the “Program Information - 121” screen:
Screen Explanation:
Shows information about the irrigation that has already finished. The information is about the water and
fertilizer delivered, the flow rate, ECpH, irrigation duration and the time and date of the last irrigation.
Irrigation Program Programming (122):
See “Basic Operation”.
Program Constants (123):
Press “Prgrms Consts.” In the “Irrigation Program Status -12” screen
and scroll down to enter “Program Constants” screen number 2 (screen number 1 was explained in
“Basic Operation”).