61
GalStar
Instruction 1.0
4. Advanced Operation
•
Condition Statuses
(5 parameters)
: Input Operation Cond; Input Pause Cond; Logic
Operation Cond; Logic Pause Cond. and Logic Fault Cond.
statuses are shown
.
The options
are:
Void, Defined, On.
•
Conditioning Sensor
(3 parameters)
: Sensor Value
– a numeric parameter
, Low Sensor
Level, High Sensor Level
statuses are shown
.
The options are:
Yes/No.
Auxiliary Program (412):
Press “Main”>”General Elemnts”>”Aux. Output”>”Aux. Prog.” to access:
Screen Explanation:
(Programmable Element Screen)
•
Operation method * :
The options are:
o
N.Active:
The auxiliary output is not active.
o
By Time:
Start Time
and
End Time
must be entered. Only stopping conditions will work.
o
By Cond:
Start Time
and
End Time
definitions are optional. If entered, the auxiliary output
will only work during the time range. If not entered the auxiliary output will only work according
to the conditions. All conditions are obviously working in this mode.
o
Operation Time – Sec:
Enter the time duration of the operation of the auxiliary output.
o
Wait Time:
Enter the time duration between the stop of one cycle and the start of the next
cycle. If zero – the auxiliary output operates continuously.
o
Operation Condition Input No.:
Enter the number of the conditioned input to start the
auxiliary output when “On”. When the conditioned input is “Off” the auxiliary output turns off.
o
Pause Conditioned Input No.:
Enter the number of the conditioned input to “Pause”
the auxiliary output. When the condition is “On” the auxiliary output is paused. When the
conditioned input is “Off” the auxiliary output program resumes.