4. Advanced Operation
•
Water Meter No.:
It is essential to enter the number when working according to volume between flushes.
•
P.D Sw. Input No.:
The number of the “Condition Input” which is connected to the “Pressure
Differential Switch”.
•
Max. Continuous. Fls:
Enter the number of continuous flushes for PD switch fault.
(See explanation in the “Filter Flush Status” section.)
•
Line Fill Delay:
Enter the time in seconds for line fill delay. (See explanation in the “Filter Flush
Status” section.)
•
Flush Pause Irr. * (Yes/No):
In order to maintain the pressure while flushing it is sometimes
necessary to stop irrigation during flushing.
•
Sust.Preced. – Sec:
When using a pressure sustaining valve it is usually necessary to first
sustain the pressure and only start flushing after a certain period of time. Enter here the number of
seconds between start sustaining and start flushing. (See more in the “Filter Flush Status” section.)
•
Flush Fail. React. * (Idle, Alarm, Pause, Fault)
Water Counter Status (182):
Press “Water Cntrs” in the “Other Elements - 18” screen to access:
Screen Explanation:
(Element Screen)
•
Water Meter Status:
The options are:
N.Active, Ready, Irrigat, UnControlled, No Pulse,
Fault, Input No., Pulse Size.
•
Measure/Nominal Flow
(2 parameters)
•
Accumulation
(3 parameters)
:
Shows the daily/seasonal accumulation and the seasonal
accumulation start date of the water meter.