![Furukawa Unic URW370C4U Series Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/furukawa-unic/urw370c4u-series/urw370c4u-series_operation-and-maintenance-manual_2349551115.webp)
12-9
U-WAVE, Radio remote control device, (Option)
If it was found normal after the system diagnosis has been completed, the mode indicator lamp
lights either one of following indication and voice message,
“Ping-pong, Remote control
ready, Remote control ready”
, is issued.
• Since priority is assigned for each mode in its information, it is to be indicated in the order of
higher priority.
Remarks
If the “mode indicator lamp” fails to make a full lighting during system
diagnosis, or voice message, “Beep, Service remote control, Service
remote control”, is issued despite the fact that the crane has not been
operated, take measures according to the section 12.
◆
3. “Trouble
inspection” (on page 12-40).
Mode
Information
Indication priority
Current operation mode is on normal radio remote control
mode.
4
Current operation mode is traveling mode.
1
Current operation mode is on outrigger radio remote con-
trol mode.
2
Hook hits against weight for over-winding alarm (over-
wound condition).
3
If the “mode indicator lamp” indicates [
], current control is on outrigger radio con-
trol mode.
No crane operation other than extension/retraction of outriggers is possible.
When operating the crane, turn the “crane/outrigger operation mode selector” switch to
“crane”.
CAUTION
Содержание URW370C4U Series
Страница 2: ......
Страница 9: ...MEMO...
Страница 19: ...4 1 4 DESCRIPTION OF CARRIER EQUIPMENT 17 19 8 10 6 14 7 9 5 2 1 4 3 14 18 17 11 12 16 20 13 URW505C4U...
Страница 22: ...MEMO...
Страница 50: ...MEMO...
Страница 54: ...MEMO...
Страница 78: ...MEMO...
Страница 150: ...MEMO...
Страница 186: ...MEMO...
Страница 204: ...MEMO...
Страница 246: ......
Страница 247: ......
Страница 248: ...HEAD OFFICE Nihonbashi nishikawa Bldg 5 3 Nihonbashi 1 chome Chuo ku Tokyo 103 0027 Japan...