42
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
2. Clear the fault by setting the FRU’s
component_state
property to
Enabled
.
This will remove the component from the ASR blacklist.
Use the FRU name that was reported in the fault in
The fault is cleared and should not show up when you run the
show faulty
command. Additionally, the Service Required LED is no longer on.
3. Reset the server.
You must reboot the server for the change to the
component_state
property to
take effect.
4. At the ILOM prompt, use the
show faulty
command to verify that no faults
are reported.
POST Output Quick Reference
POST error messages use the following syntax:
In this syntax,
c
= the core number,
s
= the strand number.
Warning messages use the following syntax:
Informational messages use the following syntax:
->
set /SYS/MB/CMP0/BR1/CH0/D0 component_state=Enabled
->
show faulty
Target | Property | Value
--------------------+------------------------+------------------
->
c:s > ERROR: TEST =
failing-test
c:s > H/W under test = FRU
c:s > Repair Instructions: Replace items in order listed by H/W
under test above
c:s > MSG = test-error-message
c:s > END_ERROR
WARNING:
message
INFO:
message
Содержание SPARC Enterprise T5140
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 44: ...18 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart ...
Страница 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 239: ......
Страница 240: ......