Servicing Motherboard Components
127
a.
All FB-DIMMs removed from the previous motherboard. Ensure that the
FB-DIMM modules are installed in the same memory configuration as they
were in before.
See
“FB-DIMM Configuration Guidelines for SPARC Enterprise T5140 Servers”
or
“FB-DIMM Configuration Guidelines for SPARC Enterprise
for guidance.
b.
SCC module. See
“Install the SCC Module” on page 117
.
6. Connect the hard drive data cables. For cable routing instructions, see
whichever of the following topics apply:
■
“Internal Cables for Onboard SAS Controller Cards in SPARC Enterprise T5140
Servers” on page 190
■
“Internal Cables for Onboard SAS Controller Cards in SPARC Enterprise T5240
Servers” on page 204
7. Install the air duct.
See
“Install the Air Duct” on page 104
8. Reinstall the motherboard-to-power distribution board ribbon cable.
9. Reinstall the PCIe and XUAI risers.
See
“Install a PCIe/XAUI Riser” on page 107
10. Install the top cover.
See
“Install the Top Cover” on page 177
.
11. Install the server into the rack.
See
“Reinstall the Server in the Rack” on page 178
12. Attach the power cables.
See
“Connect Power Cords to the Server” on page 181
.
13. Power on the server.
See
“Power On the Server Using the
or
On the Server Using the Front Panel Power Button” on page 182
Related Information
■
Содержание SPARC Enterprise T5140
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 44: ...18 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart ...
Страница 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 239: ......
Страница 240: ......