76
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
7. At the Solaris prompt, type the
cfgadm -al
command to list all drives in the
device tree, including any drives that are not configured.
This command should identify the
Ap_id
for the hard drive that you installed.
The output should indicate that the drive you installed is configured. For example,
the output should look like this:
Related Information
■
“Install a Hard Drive” on page 73
■
“Four-Drive Capable Backplane Configuration Reference” on page 77
■
“Eight-Drive Capable Backplane Configuration Reference” on page 78
■
“Sixteen-Drive Capable Backplane Configuration Reference” on page 79
#
cfgadm -al
Ap_id
Type
Receptacle
Occupant
Condition
c0 scsi-bus connected configured unknown
c0::dsk/c1t0d0 disk connected configured unknown
c0::dsk/c1t1d0 disk connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb0/3 unknown empty unconfigured ok
usb1/1 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
usb1/3 unknown empty unconfigured ok
usb2/1 unknown empty unconfigured ok
usb2/2 unknown empty unconfigured ok
usb2/3 unknown empty unconfigured ok
usb2/4 unknown empty unconfigured ok
usb2/5 unknown empty unconfigured ok
usb2/6 unknown empty unconfigured ok
usb2/7 unknown empty unconfigured ok
usb2/8 unknown empty unconfigured ok
----------------------------
Содержание SPARC Enterprise T5140
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 44: ...18 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart ...
Страница 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 239: ......
Страница 240: ......