86
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
FIGURE:
Removing FB-DIMMs
8. Grasp the top corners of the faulty FB-DIMM and lift it out of its slot.
9. Place the FB-DIMM on an antistatic mat.
10. Repeat
through
for any other FB-DIMMs you intend to remove.
11. If you do not plan to install replacement FB-DIMMs at this time, install filler
panels in the empty slots.
Related Information
■
“Install Replacement FB-DIMMs” on page 86
■
“Verify Successful Replacement of Faulty FB-DIMMs” on page 88
▼
Install Replacement FB-DIMMs
Before beginning this procedure, ensure that you are familiar with the information
provided in these topics:
■
“Preparing to Service the System” on page 57
■
“FB-DIMM Configuration Guidelines for SPARC Enterprise T5140 Servers” on
page 94
Note –
If the server is already extended and open, begin the procedure at
.
1. Extend the server to the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 63
.