32
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
▼
Display FRU Information With the
show
Command
●
At the
->
prompt, enter the
show
command.
The following example illustrates
show
command output for a memory module
(FB-DIMM).
Related Information
■
“Diagnostics Tools Quick Reference” on page 17
▼
Create an ALOM CMT Shell
The default shell for the service processor is the ILOM shell. You can use the ALOM
CMT compatibility shell to emulate the ALOM CMT interface that was supported on
an earlier generation of CMT servers.
->
show /SYS/MB/CMP0/BR0/CH0/D0
/SYS/MB/CMP0/BR0/CH0/D0
Targets:
R0
R1
SEEPROM
SERVICE
PRSNT
T_AMB
Properties:
type = DIMM
component_state = Enabled
fru_name = 1024MB DDR2 SDRAM FB-DIMM 333 (PC2 5300)
fru_description = FBDIMM 1024 Mbyte
fru_manufacturer = Micron Technology
fru_version = FFFFFF
fru_part_number = 18HF12872FD667D6D4
fru_serial_number = d81813ce
fault_state = OK
clear_fault_action = (none)
Commands:
cd