![background image](http://html.mh-extra.com/html/fujitsu/sparc-enterprise-t5140/sparc-enterprise-t5140_service-manual_121354218.webp)
192
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
FIGURE:
Internal Cables for the Onboard SAS Controller Card (Eight-Disk Capable
SPARC Enterprise T5140 Servers)
Figure Legend
1
Top cover safety interlock
2
Motherboard to PDB cable
3
Hard drive data cables
TABLE:
Data Cable Routing Details (Four-Disk Capable SPARC Enterprise T5140 Servers)
Item
FRU
Connections
Routing notes
3
HDD data
cable
Lower cable in the figure: From
J4101(SAS0) on the motherboard to
J0301 (P2) on the hard drive
backplane.
Routed between CMP Module 0 (CMP0) and
CMP Module 1 (CMP1), then under the chassis
center wall, and then under the fan power board.
3
HDD data
cable
Upper cable in the figure: From
J4102(SAS1) on the motherboard to
J0302 (P3) on the hard drive
backplane.
Routed along CMP Module 1 (CMP1), then
under the chassis center wall, and then under the
PDB board.