90
SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
Note –
Depending on the configuration of ILOM POST variables and whether POST
detected faults or not, the system might boot, or the system might remain at the
ok
prompt. If the system is at the
ok
prompt, type
boot
.
d. Return the virtual keyswitch to Normal mode.
e. Switch to the system console and type the Solaris OS
fmadm faulty
command.
No memory faults should be displayed.
If faults are reported, refer to the diagnostics instructions described in
Troubleshooting Overview” on page 23
for guidance in troubleshooting the
fault.
5. Switch to the ILOM command shell.
6. Run the
show faulty
command.
If the
show faulty
command reports a fault with a UUID go on to
. If
show faulty
does
not
report a fault with a UUID, you are done with the
verification process.
->
set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
#
fmadm faulty
->
show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/
| uuid
| 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
Содержание SPARC Enterprise T5140
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 44: ...18 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart ...
Страница 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 239: ......
Страница 240: ......