Servicing Motherboard Components
89
3. Use the
set
command to enable the FB-DIMM that was disabled by POST.
In most cases, replacement of a faulty FB-DIMM is detected when the service
processor is power cycled. In those cases, the fault is automatically cleared from
the system. If
show faulty
still displays the fault, clear it with the
set
command.
4. Perform the following steps to verify the repair:
a. Set the virtual keyswitch to
diag
so that POST will run in Service mode.
b. Power cycle the system.
Note –
The server takes about one minute to power off. Use the
show /HOST
command to determine when the host has been powered off. The console will display
status=Powered Off
.
c. Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output
indicates that POST did not detect any faults:
->
set /SYS/MB/CMP0/BR0/CH0/D0 component_state=Enabled
->
set /SYS/keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’
->
stop /SYS
Are you sure you want to stop /SYS (y/n)?
y
Stopping /SYS
->
start /SYS
Are you sure you want to start /SYS (y/n)?
y
Starting /SYS
->
start /SYS/console
.
.
.
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Содержание SPARC Enterprise T5140
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 44: ...18 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 FIGURE Diagnostics Flowchart ...
Страница 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Страница 239: ......
Страница 240: ......