Servicing Motherboard Components
95
■
SPARC Enterprise T5140 servers support these FB-DIMM configurations:
■
8 FB-DIMMs (Group 1 in
FIGURE: FB-DIMM Configuration for SPARC
Enterprise T5140 Servers on page 95
■
12 FB-DIMMs (Groups 1 and 2 in
FIGURE: FB-DIMM Configuration for SPARC
Enterprise T5140 Servers on page 95
■
16 FB-DIMMs (Groups 1, 2, and 3 in
FIGURE: FB-DIMM Configuration for
SPARC Enterprise T5140 Servers on page 95
)
■
All FB-DIMMs within a single CMP branch must have the same capacity.
■
If the System Firmware is at least version 7.1.7.f, the FB-DIMM capacities on
different CPUs can be different.
■
When replacing a faulty FB-DIMM, the replacement FB-DIMM
must
have the same
FRU part number as the FB-DIMM being replaced.
If you are not able to obtain a replacement FB-DIMM with the same FRU part
number, may need to replace all the FB-DIMMs in the branch to ensure that all
FB-DIMMs in that branch have the same FRU part number.
FIGURE:
FB-DIMM Configuration for SPARC Enterprise T5140 Servers
The following figure shows the physical location for the FB-DIMMs on the
motherboard in a SPARC Enterprise T5140 server.