zpool
status
rpool
pool:
rpool
state:
ONLINE
scan:
resilvered
28.7M
in
0h0m
with
0
errors
on
Tue
Jan
21
10:10:01
2014
config:
NAME
STATE
READ
WRITE
CKSUM
rpool
ONLINE
0
0
0
mirror-0
ONLINE
0
0
0
c2t50000393E802CCE2d0s0
ONLINE
0
0
0
errors:
No
known
data
errors
#
ldm
start-reconf
primary
Initiating
a
delayed
reconfiguration
operation
on
the
primary
domain.
All
configuration
changes
for
other
domains
are
disabled
until
the
primary
domain
reboots,
at
which
time
the
new
configuration
for
the
primary
domain
will
also
take
effect.
#
ldm
list-io
|
grep
primary
PCIE0
BUS
PCIE0
primary
IOV
PCIE4
BUS
PCIE4
primary
IOV
PCIE8
BUS
PCIE8
primary
IOV
PCIE12
BUS
PCIE12
primary
IOV
/BB0/CMUL/NET0
PCIE
PCIE0
primary
OCC
/BB0/CMUL/SASHBA
PCIE
PCIE0
primary
OCC
/BB0/CMUL/NET2
PCIE
PCIE4
primary
OCC
/BB1/CMUL/NET0
PCIE
PCIE8
primary
OCC
If
there
are
any
other
devices
on
BB#01
in
use,
release
the
redundant
configurations
and
stop
using
the
devices.
For
how
to
release
the
redundant
configurations
and
how
to
stop
using
the
devices,
refer
to
the
documents
of
software
in
the
redundant
configurations
and
Oracle
Solaris.
b.
Delete
the
I/O
configuration
of
the
control
domain.
b-1)
Out
of
the
physical
I/O
devices
assigned
to
the
control
domain,
delete
the
root
complex
of
BB#01.
b-2)
Change
the
control
domain
to
the
delayed
reconfiguration
mode.
This
operation
is
not
required
if
the
root
complexes
are
reconfigured
dynamically.
The
following
shows
the
software
conditions
to
reconfigure
the
root
complexes
dynamically.
-
XCP
2240
or
later
-
Oracle
VM
Server
for
SPARC
3.2
or
later
-
Oracle
Solaris
11.2
SRU11.2.8
or
later
b-3)
Execute
the
ldm
list-io
command
to
check
the
root
complexes
assigned
to
the
primary
domain.
The
following
example
tells
that
the
root
complexes
with
the
device
of
BB1
are
PCIE8
and
PCIE12.
Fujitsu
M10/SPARC
M10
Systems
Installation
Guide
・
July
2015
282
Содержание M10 Series
Страница 1: ...Fujitsu M10 SPARC M10 Systems Installation Guide Manual Code C120 E678 12EN July 2015 ...
Страница 10: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 x ...
Страница 156: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 142 ...
Страница 169: ...A B Figure 4 14 Locations for passing cables between the racks Chapter 4 Configuring Building Block Connections 155 ...
Страница 176: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 162 ...
Страница 208: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 194 ...
Страница 240: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 226 ...
Страница 252: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 238 ...
Страница 290: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 276 ...
Страница 310: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 296 ...
Страница 336: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 322 ...
Страница 368: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 354 ...
Страница 374: ...Fujitsu M10 SPARC M10 Systems Installation Guide July 2015 360 ...