Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
462
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
End of procedure
11.2.3.2
Setup Firewall
This function configures a firewall for each service.
Configuration is required for each MNT, RMT and FST port.
•
MNT port
The MNT port is used for general communication between the ETERNUS DX Disk storage
system and the external hosts.
•
RMT port
The RMT port is used when the line must be separated from the MNT port.
•
FST port
The FST port is used for maintaining the ETERNUS DX Disk storage system.
The procedure to set a firewall is as follows:
Procedure
1
Click [Setup Firewall] in [Action].
2
Specify whether to enable or disable the connection of each service, and click
the [Modify] button.
●
New Setting
•
HTTP
Specify whether to enable or disable the HTTP connection. Select the checkbox to
enable the connection.
HTTP is used when accessing from GUI.
Device management operation cannot be continued if the IP address
of the ETERNUS DX Disk storage system has been changed.
Logging on again with the new IP address is required.
•
The FST port settings are only required when the storage system is
ETERNUS DX410 S2/DX440 S2.
•
If both the HTTP connection and the HTTPS connection have been
disabled, GUI cannot access the ETERNUS DX Disk storage system.
•
If both the Telnet connection and the SSH connection have been
disabled, CLI cannot access the ETERNUS DX Disk storage system.
•
If ports of all the services are disabled, access to the ETERNUS DX
Disk storage system is not allowed.
To configure the network environment of the ETERNUS DX Disk storage
system, use the procedure in
"11.2.3.1 Setup Network Environment" (page
.