Chapter 9 Connectivity Management
9.2 Functions in the Action Area for Connectivity
ETERNUS Web GUI User’s Guide
353
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
4
Click the [Done] button to return to the [Port Group] screen.
End of procedure
9.2.3.7
Configure FC Port
This function sets the connection information between the FC port of the ETERNUS DX Disk
storage system and the host or the connection information between local and remote devices.
The procedure to set FC port parameters is as follows:
Procedure
1
Select which FC port to set the parameters for (multiple selections can be made)
and click [Configure FC Port] in [Action].
An error screen appears in the following conditions:
•
When the port group name overlaps with an existing port group
name (port group names cannot overlap with any other port group
names, irrespective of the CA types.)
•
When no ports are registered in a port group, or when nine or
more ports are registered in a port group
•
When the specified port does not exist in the ETERNUS DX Disk
storage system
•
When the CA type of the selected port differs from the CA type of
the existing ports in the port group
•
When the port mode of the selected port is other than "CA"
•
When there are ports of which affinity mode is enabled (On) and
disabled (Off) existing together
•
When the affinity mode (On/Off) of the selected port differs from
the affinity mode of the existing ports in the port group
When changing port parameters during operation, stop access from the
server that is allocated to the target port. Host access does not need to be
stopped to change the port parameters of newly added CA ports.
•
There are two types of port modes for FC ports; CA and RA. CA is used
for connecting to the server and RA is used for REC. To switch between
"RA" and "CA", refer to
"9.2.3.11 Modify Port Mode" (page 373)
. The
default value is "CA".
•
For more details on the parameter settings of FC-CA, refer to "User’s
Guide -Server Connection-" for each OS type.