9. TEST OPERATION CONTROL
Touch the [Test run] in the “Maintenance” screen.
The “Test Run” screen is displayed.
Touch [OK] to return to the Maintenance screen, and start the test run.
The test run will automatically end is approximately 60 min.
If you wish to cancel the test run before it is complete, return to the “Monitor Mode screen”, and touch
the On/Off button.
With Wired Remote Control
Under the condition where the air conditioner runs, press the TEST RUN button, and
the test operation control mode will appear.
During test running, the Operation LED and Timer LED of the air conditioner body blinks simultaneously.
Set the test operation mode, and the compressor will continue to run regardless of whether the room
temperature sensor detects.
The test operation mode is released if 60 minutes have passed after setting up the test operation.
With Wireless Remote Control
*Installer password is required.
If the password has been charged from the default setting “0000”,
contact to the installer.