04-14
Compressor
ON
OFF
Indoor fan
Setting air flow
OFF
Function setting 49
Note
Setting air flow
Work
Set by remote controller
This function can be set by 2 wire
remote controller and the wireless
remote controller.
In the case of 3 wire remote controller
is connected, set it to 0 or 1.
3 wire remote controller can’t be set it.
10
0
1
2
30
60
180
60
180
60 10
30
(sec)
S-low
Factory setting
8. DEFROST OPERATION
When defrost operation starts, indoor fan runs
according to cool air prevention control for 20 seconds.
And the fan is stopped if 20 seconds have passed.
When 60 seconds have passed after defrost operation is released,
the fan runs according to cool air prevention control.
7. FAN CONTROL FOR ENERGY SAVING
When the air flow setting except AUTO mode,
the indoor fan motor will run as below.
Quiet or S-low
Содержание AMUG24LMAS