Type
Inverter heat pump
Model name
AOYG24KBTB
AOYG30KBTB
Power supply
230 V ~ 50 Hz
Power supply intake
Outdoor unit
Available voltage range
198—264 V
Starting current
A
8.4
11.1
Fan
Airflow rate
Cooling
m
3
/h
2,700
3,750
Heating
2,700
3,750
Type × Q'ty
Propeller × 1
Motor output
W
49
100
Sound pressure level *1
Cooling
dB (A)
53
53
Heating
54
55
Sound power level
Cooling
dB (A)
65
68
Heating
66
69
Heat exchanger type
Dimensions
(H × W × D)
mm
Main1: 672 × 881 × 18.19
Main2: 672 × 851 × 18.19
Main1: 756 × 905 × 18.19
Main2: 756 × 905 × 18.19
Fin pitch
1.30
1.45
Rows × Stages
1 × 32
1 × 36
Pipe type
Copper
Fin
Type (Material)
Aluminum
Surface treatment
PC fin
Blue fin
Compressor
Type
DC Twin rotary
Motor output
W
1,060
1,500
Refrigerant
Type (Global warming potential)
R32 (675)
Factory charge
g
1,250
1,900
Refrigerant oil
Type
RmM68AF
FW68D
Amount
cm
3
400
600
Enclosure
Material
Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
716 × 820 × 315
788 × 940 × 320
Gross
776 × 961 × 450
966 × 1,027 × 445
Weight
Net
kg
42
52
Gross
46
60
Connection pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Ø9.52 (Ø3/8)
Gas
Ø12.70 (Ø1/2)
Ø15.88 (Ø5/8)
Method
Flare
Pre-charge length
m
20
30
Max. length
30
50
Max. height difference
25
30
Operation range
Cooling
°C
-15 to 46
Heating
-15 to 24
Drain hose
Material
PP
LDPE
Tip diameter
mm
Ø13.0 (I. D.), Ø16.0 to Ø16.7 (O. D.)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• This data is based on EN 14511 standard.
1-2. Outdoor unit
- (01-8) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Содержание ABYG18KRTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2020 11 16 SR_CH01_AB004EF_03 ...
Страница 24: ...2 2 Outdoor unit 01 18 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 25: ...2 TECHNICAL DATA AND PARTS LIST 2020 12 09 SR_CH02_AB004EF_05 ...
Страница 71: ...3 TROUBLESHOOTING 2020 07 01 SR_CH03_AB004EF_01 ...
Страница 74: ......
Страница 138: ...5 2 Outdoor unit 03 64 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 139: ...4 CONTROL AND FUNCTIONS 2020 07 01 SR_CH04_AB004EF_01 ...