8-3. Current release control
The compressor frequency is controlled so that the outdoor unit input current does not exceeds cur-
rent limit value set according to the outdoor temperature.
The compressor frequency returns according to the operation mode, when the current becomes low-
er than the release value.
¢
Model: AOYG18KBTB
Operation mode
Outdoor temp. (Ta)
Trigger condition
Release condition
Cooling
50°C ≤ Ta
4.5 A
4.0 A
46°C ≤ Ta < 50°C
4.5 A
4.0 A
40°C ≤ Ta < 46°C
6.0 A
5.5 A
12°C ≤ Ta < 40°C
10.0A
9.5 A
2°C ≤ Ta < 12°C
10.0 A
9.5 A
Ta < 2°C
10.0 A
9.5 A
Heating
17°C ≤ Ta
7.0 A
6.5 A
12°C ≤ Ta < 17°C
9.0 A
8.5 A
5°C ≤ Ta < 12°C
10.5 A
10.0 A
Ta < 5°C
10.5 A
10.0 A
¢
Model: AOYG22KBTB
Operation mode
Outdoor temp. (Ta)
Trigger condition
Release condition
Cooling
50°C ≤ Ta
7.0 A
6.5 A
46°C ≤ Ta < 50°C
7.0 A
6.5 A
40°C ≤ Ta < 46°C
9.5 A
9.0 A
12°C ≤ Ta < 40°C
10.5 A
10.0 A
2°C ≤ Ta < 12°C
10.5 A
10.0 A
Ta < 2°C
10.5 A
10.0 A
Heating
17°C ≤ Ta
8.0 A
7.5 A
12°C ≤ Ta < 17°C
9.0 A
8.5 A
5°C ≤ Ta < 12°C
11.0 A
10.5 A
Ta < 5°C
11.0 A
10.5 A
¢
Model: AOYG24KBTB
Operation mode
Outdoor temp. (Ta)
Trigger condition
Release condition
Cooling
50°C ≤ Ta
7.0 A
6.5 A
46°C ≤ Ta < 50°C
7.0 A
6.5 A
40°C ≤ Ta < 46°C
9.5 A
9.0 A
12°C ≤ Ta < 40°C
12.0 A
11.5 A
2°C ≤ Ta < 12°C
12.0 A
11.5 A
Ta < 2°C
12.0 A
11.5 A
Heating
17°C ≤ Ta
8.5 A
8.0 A
12°C ≤ Ta < 17°C
9.5 A
9.0 A
5°C ≤ Ta < 12°C
11.0 A
10.5 A
Ta < 5°C
11.0 A
10.5 A
8-3. Current release control
- (04-39) -
8. Various protections
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание ABYG18KRTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2020 11 16 SR_CH01_AB004EF_03 ...
Страница 24: ...2 2 Outdoor unit 01 18 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 25: ...2 TECHNICAL DATA AND PARTS LIST 2020 12 09 SR_CH02_AB004EF_05 ...
Страница 71: ...3 TROUBLESHOOTING 2020 07 01 SR_CH03_AB004EF_01 ...
Страница 74: ......
Страница 138: ...5 2 Outdoor unit 03 64 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 139: ...4 CONTROL AND FUNCTIONS 2020 07 01 SR_CH04_AB004EF_01 ...
Страница 141: ...8 8 High temperature and high pressure release control 04 42 CONTENTS continued ...
Страница 142: ......
Страница 187: ...5 FILED WORKING 2020 07 01 SR_CH05_AB004EF_01 ...